P0D18 Powertrain

Battery Charging System A High Voltage Interlock CircuitCircuit High

The HV interlock circuit of battery charging system A reports a circuit high condition. Safety interlock chain may be compromised.

Affected components

  • Bcs a hv interlock
  • Wiring harness
  • Bms

Common causes

  • High likelihood: Wire shorted to B+
  • Medium likelihood: Pull-down resistor open
  • Low likelihood: Connector pins corroded - high contact resistance

Diagnostic notes

  • The malfunction indicator lamp may illuminate
  • Reduced-power or limp mode may occur

Sources

Diagnostic information is provided for reference only. Confirm the code with a compatible scan tool and follow the vehicle manufacturer's service procedures before replacing components.