NOx Sensor Performance - Slow Response Low to High (Bank 1 Sensor 1)

NOx sensor on bank 1 sensor 1 responds too slowly when NOx concentration rises (typically observed when SCR dosing is reduced or stopped). The sensor has aged or its protection cap is clogged.

Affected components

  • Nox sensor

Common causes

  • High likelihood: Sensor aged or protection cap clogged
  • Low likelihood: Sensor element aged beyond calibration window
  • Low likelihood: Sensor element contaminated by oil, soot or coolant

Possible symptoms

  • Check engine light or NOx warning on
  • AdBlue/DEF level or quality warning
  • Possible no-start countdown after ignore period
  • Failed emissions inspection (NOx)

Diagnostic notes

  • The malfunction indicator lamp may illuminate
  • This code can affect emissions

Related codes

Sources

Diagnostic information is provided for reference only. Confirm the code with a compatible scan tool and follow the vehicle manufacturer's service procedures before replacing components.