EGR Cooler Coolant Pump Performance Stuck Off
The pump is electrically intact but does not deliver flow when commanded - typically a worn impeller or seized rotor.
Affected components
- Egr cooler coolant pump
Common causes
- High likelihood: Pump impeller worn or rotor seized
- Low likelihood: Carbon or debris buildup preventing free movement
- Low likelihood: Component wear with age - mechanical play
Possible symptoms
- Check engine light on
- Pinging or knocking under load
- Power loss and hesitation
- Possible rough idle
- Failed emissions inspection (NOx)
Diagnostic notes
- The malfunction indicator lamp may illuminate
- This code can affect emissions
Sources