Generator Lamp/L-Terminal Circuit High

The L-terminal feedback from the alternator reads above the upper limit — short to supply or open ground side. Charging diagnostics cannot run cleanly.

Affected components

  • Alternator
  • Charging warning lamp wiring

Common causes

  • High likelihood: L-terminal shorted to supply
  • Medium likelihood: Alternator regulator failed
  • Low likelihood: Connector pins corroded - high contact resistance

Diagnostic notes

  • The malfunction indicator lamp may illuminate

Related codes

Sources

Diagnostic information is provided for reference only. Confirm the code with a compatible scan tool and follow the vehicle manufacturer's service procedures before replacing components.