P2517 Powertrain

A/C Refrigerant Pressure Sensor B Circuit Low

A/C refrigerant pressure sensor B signal voltage reads below the lower limit. Either a short to ground in the signal wire, an open reference voltage at the sensor, or an internal short. The ECM ignores the reading and disables A/C closed-loop control until the circuit recovers.

Affected components

  • Ac pressure sensor b
  • Sensor wiring

Common causes

  • High likelihood: Signal wire shorted to ground
  • Medium likelihood: Missing 5 V reference at the sensor
  • Low likelihood: Connector pins corroded - high contact resistance

Diagnostic notes

  • The malfunction indicator lamp may illuminate

Related codes

Sources

Diagnostic information is provided for reference only. Confirm the code with a compatible scan tool and follow the vehicle manufacturer's service procedures before replacing components.