Alternative Fuel Tank Shutoff Valve C Control Circuit Low
The control circuit of alternative fuel tank shutoff valve C reports a control circuit low condition. Tank isolation cannot be commanded as expected on multi-tank CNG/LPG systems.
Affected components
- Alt fuel tank shutoff valve c
- Wiring harness
- Afcm
Common causes
- High likelihood: Control wire shorted to ground
- Medium likelihood: Internal short in valve coil
- Low likelihood: Connector pins corroded - high contact resistance
Diagnostic notes
- The malfunction indicator lamp may illuminate
- This code can affect emissions
- Reduced-power or limp mode may occur
Related codes
Sources
Diagnostic information is provided for reference only. Confirm the code with a compatible scan tool and follow the vehicle manufacturer's service procedures before replacing components.