Skip to content
P2D73 Powertrain

Battery Charging System Negative Contactor D Control Circuit/Open

The negative contactor D of the battery charging system reports a control circuit/open condition. HV charging path cannot be commanded reliably.

Affected components

  • Bcs neg contactor d
  • Wiring harness
  • Bms

Common causes

  • High likelihood: Open in coil control wire
  • Medium likelihood: Open contactor coil
  • Low likelihood: Pin pushed back out of connector body

Diagnostic notes

  • The malfunction indicator lamp may illuminate
  • Reduced-power or limp mode may occur

Related codes

Sources

Diagnostic information is provided for reference only. Confirm the code with a compatible scan tool and follow the vehicle manufacturer's service procedures before replacing components.