DC/AC Converter A High Voltage Power Outlet "A" Circuit/Open
Open circuit on the high-voltage power outlet "A" of DC/AC converter A. The outlet supplies 110/230 V AC from the HV battery on EVs/hybrids (vehicle-to-load).
Affected components
- Dc ac converter a
- Hv outlet a
Common causes
- High likelihood: Outlet wiring open
- Low likelihood: Pin pushed back out of connector body
- Low likelihood: Cracked solder joint inside the module or sensor
Possible symptoms
- Warning light or symbol related to the affected system
- Comfort or safety function impaired
Diagnostic notes
- The malfunction indicator lamp may illuminate
Related codes
Sources