Excessive Time To Enter Closed Loop NOx Adsorber Control
The NOx adsorber control did not enter closed-loop operation within the calibrated time after engine start — typically a slow-warming NOx sensor or pre-heat heater fault.
Affected components
- Nox adsorber catalyst
- Nox sensor
Common causes
- High likelihood: NOx sensor heater weak
Possible symptoms
- Check engine light or NOx warning on
- AdBlue/DEF level or quality warning
- Possible no-start countdown after ignore period
- Failed emissions inspection (NOx)
Diagnostic notes
- The malfunction indicator lamp may illuminate
- This code can affect emissions
Sources