O2 Sensor Positive Current Control Circuit High (Bank 1 Sensor 2)
O2 positive current line on bank 1 sensor 2 stuck high — short to B+. A drifted or sluggish lambda sensor lets the mixture run lean or rich without correction — fuel economy and emissions suffer immediately.
Affected components
- Oxygen sensor
Common causes
- High likelihood: Short to B+
- Low likelihood: Connector pins corroded - high contact resistance
- Low likelihood: Supply wire pinched against B+ source
Possible symptoms
- Check engine light on
- Increased fuel consumption
- Possible rough idle or hesitation
- Failed emissions test
Diagnostic notes
- The malfunction indicator lamp may illuminate
- This code can affect emissions
Related codes
Sources
Diagnostic information is provided for reference only. Confirm the code with a compatible scan tool and follow the vehicle manufacturer's service procedures before replacing components.