EVAP System Leak Detection Pump Heater Control Circuit High
Same as P240A with the control line shorted to supply. The sensor heater warms the element to operating temperature (~600 °C); without it the lambda sensor stays inactive in closed loop and the ECM cannot trim mixture.
Affected components
- Evap leak detection pump heater
Common causes
- High likelihood: Control line shorted to supply
- Low likelihood: Connector pins corroded - high contact resistance
- Low likelihood: Supply wire pinched against B+ source
Possible symptoms
- Check engine light on
- Possible smell of fuel near tank or engine bay
- Failed emissions inspection
- Loose-cap warning may appear
Diagnostic notes
- The malfunction indicator lamp may illuminate
- This code can affect emissions
Sources
Diagnostic information is provided for reference only. Confirm the code with a compatible scan tool and follow the vehicle manufacturer's service procedures before replacing components.