P2470 Powertrain

Exhaust Gas Temperature Sensor Circuit Intermittent Bank 1 Sensor 3

The exhaust gas temperature sensor 3 on bank 1 (often after the DPF) shows intermittent dropouts. Erratic readings disturb DPF regeneration logic.

Affected components

  • Exhaust gas temperature sensor
  • Egt wiring

Common causes

  • High likelihood: Intermittent connector
  • Medium likelihood: Chafed wiring near hot exhaust
  • Low likelihood: Harness routed against vibrating component

Diagnostic notes

  • The malfunction indicator lamp may illuminate
  • This code can affect emissions
  • A drive cycle may be required after repair

Sources

Diagnostic information is provided for reference only. Confirm the code with a compatible scan tool and follow the vehicle manufacturer's service procedures before replacing components.