Hybrid/EV Battery Pack Cooling Fan 2 Control Circuit Low
The HV battery pack cooling fan 2 reports a control circuit low condition. Battery thermal management is impaired.
Affected components
- Hybrid battery cooling fan 2
- Wiring harness
- Bms
Common causes
- High likelihood: Wire shorted to ground
- Medium likelihood: Internal motor short
- Low likelihood: Connector pins corroded - high contact resistance
Possible symptoms
- EV/hybrid system warning light on
- Reduced power output or limp mode
- Charging may fail or be slowed
- Reduced electric range
Diagnostic notes
- The malfunction indicator lamp may illuminate
- Reduced-power or limp mode may occur
Sources