Drive Motor A Inverter Power Supply Circuit/Open
The power supply circuit of drive motor A inverter reports a circuit/open condition. Inverter operation may be impaired.
Affected components
- Drive motor a inverter
- Wiring harness
- Hybrid control module
Common causes
- High likelihood: Open in supply wire
- Medium likelihood: Supply fuse blown
- Low likelihood: Pin pushed back out of connector body
Possible symptoms
- EV/hybrid system warning light on
- Reduced motor power or torque
- Possible limp mode or vehicle shutdown
Diagnostic notes
- The malfunction indicator lamp may illuminate
- Reduced-power or limp mode may occur
Related codes