P2017 Powertrain

Intake Manifold Runner Position Sensor/Switch Circuit High (Bank 1)

The IMRC position sensor signal on bank 1 reads above the upper limit. Typically a short to supply, an open ground reference, or a sensor that failed high.

Affected components

  • Imrc position sensor
  • Imrc wiring

Common causes

  • High likelihood: Signal wire shorted to supply
  • Medium likelihood: Sensor ground open
  • Low likelihood: Connector pins corroded - high contact resistance

Diagnostic notes

  • The malfunction indicator lamp may illuminate
  • This code can affect emissions
  • A drive cycle may be required after repair

Related codes

Sources

Diagnostic information is provided for reference only. Confirm the code with a compatible scan tool and follow the vehicle manufacturer's service procedures before replacing components.