コンテンツに進む
P225A Powertrain

NOx Sensor Calibration Memory (Bank 1 Sensor 1)

The factory calibration memory of the NOx sensor on bank 1 sensor 1 cannot be read or contains a checksum error. Each NOx sensor ships with a unique calibration table programmed at the factory.

Affected components

  • Nox sensor

Common causes

  • High likelihood: Sensor calibration memory corrupt
  • Low likelihood: Module software outdated, reflash may resolve
  • Low likelihood: Supply voltage outside specification

Possible symptoms

  • Check engine light or NOx warning on
  • AdBlue/DEF level or quality warning
  • Possible no-start countdown after ignore period
  • Failed emissions inspection (NOx)

Diagnostic notes

  • The malfunction indicator lamp may illuminate
  • This code can affect emissions

Related codes

Sources

Diagnostic information is provided for reference only. Confirm the code with a compatible scan tool and follow the vehicle manufacturer's service procedures before replacing components.