SCR Inducement Forced Engine Shutdown
The SCR inducement strategy (mandatory regulatory measure to enforce AdBlue refilling and emissions compliance) has reached the final stage and shut down the engine. Refill AdBlue and clear inducement fault to restart.
Affected components
- Scr system
- Reductant tank
Common causes
- High likelihood: AdBlue tank empty or out of compliance
Possible symptoms
- Check engine light or NOx warning on
- AdBlue/DEF level or quality warning
- Possible no-start countdown after ignore period
- Failed emissions inspection (NOx)
Diagnostic notes
- The malfunction indicator lamp may illuminate
- This code can affect emissions
Sources
Diagnostic information is provided for reference only. Confirm the code with a compatible scan tool and follow the vehicle manufacturer's service procedures before replacing components.