コンテンツに進む
P24A8 Powertrain

EGR Cooler Coolant Pump Performance Stuck Off

The pump is electrically intact but does not deliver flow when commanded - typically a worn impeller or seized rotor.

Affected components

  • Egr cooler coolant pump

Common causes

  • High likelihood: Pump impeller worn or rotor seized
  • Low likelihood: Carbon or debris buildup preventing free movement
  • Low likelihood: Component wear with age - mechanical play

Possible symptoms

  • Check engine light on
  • Pinging or knocking under load
  • Power loss and hesitation
  • Possible rough idle
  • Failed emissions inspection (NOx)

Diagnostic notes

  • The malfunction indicator lamp may illuminate
  • This code can affect emissions

Sources

Diagnostic information is provided for reference only. Confirm the code with a compatible scan tool and follow the vehicle manufacturer's service procedures before replacing components.