Actuator Supply Voltage D Circuit Low

The fourth actuator supply rail is below the expected voltage. Wiring faults of this kind typically come from chafing, water ingress at connector seals, or pin push-back — a wiggle test on the harness while the code is active often confirms the location.

Affected components

  • Actuator supply d
  • Charging system

Common causes

  • High likelihood: Load on the rail shorted to ground
  • Medium likelihood: Battery condition causes voltage to drop
  • Low likelihood: Connector pins corroded - high contact resistance

Diagnostic notes

  • The malfunction indicator lamp may illuminate

Related codes

Sources

Diagnostic information is provided for reference only. Confirm the code with a compatible scan tool and follow the vehicle manufacturer's service procedures before replacing components.