Wastegate Position Sensor A Circuit Low
Voltage on the wastegate position sensor A signal line is below the expected window. Wire shorted to ground or sensor short.
Affected components
- Wastegate position sensor a
- Wiring harness
- Ecm
Common causes
- High likelihood: Signal wire shorted to ground
- Medium likelihood: Internal sensor short
- Low likelihood: Connector pins corroded - high contact resistance
Diagnostic notes
- The malfunction indicator lamp may illuminate
- This code can affect emissions
- Reduced-power or limp mode may occur
Related codes
Sources
Diagnostic information is provided for reference only. Confirm the code with a compatible scan tool and follow the vehicle manufacturer's service procedures before replacing components.