P2ABC Powertrain

Wastegate Position Sensor B Circuit High

Voltage on the wastegate position sensor B signal line is above the expected window. Wire shorted to B+ or sensor open.

Affected components

  • Wastegate position sensor b
  • Wiring harness
  • Ecm

Common causes

  • High likelihood: Signal wire shorted to B+
  • Medium likelihood: Open position sensor
  • Low likelihood: Connector pins corroded - high contact resistance

Diagnostic notes

  • The malfunction indicator lamp may illuminate
  • This code can affect emissions
  • Reduced-power or limp mode may occur

Related codes

Sources

Diagnostic information is provided for reference only. Confirm the code with a compatible scan tool and follow the vehicle manufacturer's service procedures before replacing components.