Hybrid/EV Battery Contactor Control Supply Circuit/Low
The supply circuit for the hybrid battery contactor control reports a low condition. Contactor coils may not energise as expected.
Affected components
- Hybrid battery contactor control supply
- Wiring harness
- Bms
Common causes
- High likelihood: Supply wire shorted to ground
- Medium likelihood: Supply rail collapses under load
- Low likelihood: Pack cell imbalance approaching service threshold
Possible symptoms
- EV/hybrid system warning light on
- Reduced power output or limp mode
- Charging may fail or be slowed
- Reduced electric range
Diagnostic notes
- The malfunction indicator lamp may illuminate
- Reduced-power or limp mode may occur