コンテンツに進む
P2D6E Powertrain

Battery Charging System Positive Contactor D Control Circuit Low

The positive contactor D of the battery charging system reports a control circuit low condition. HV charging path cannot be commanded reliably.

Affected components

  • Bcs pos contactor d
  • Wiring harness
  • Bms

Common causes

  • High likelihood: Control wire shorted to ground
  • Medium likelihood: Internal short in contactor coil
  • Low likelihood: Connector pins corroded - high contact resistance

Diagnostic notes

  • The malfunction indicator lamp may illuminate
  • Reduced-power or limp mode may occur

Related codes

Sources

Diagnostic information is provided for reference only. Confirm the code with a compatible scan tool and follow the vehicle manufacturer's service procedures before replacing components.

You might like