コンテンツに進む
U064E Network

Lost Communication With EGR Cooler Bypass Position Sensor Bank 1

The vehicle bus reports loss of communication with smart EGR cooler bypass position sensor on bank 1. EGR cooling switching cannot be verified; emissions strategy may revert to fully cooled mode.

Affected components

  • Egr cooler bypass position sensor bank 1
  • Vehicle bus wiring

Common causes

  • High likelihood: Bus wiring open or shorted
  • Medium likelihood: Module without power or ground
  • Medium likelihood: Module failed

Possible symptoms

  • Multiple warning lights may illuminate
  • Affected modules may go into limp mode or shut down
  • Specific functions inoperative depending on module
  • Diagnostic tools may show communication faults

Diagnostic notes

  • The malfunction indicator lamp may illuminate
  • This code can affect emissions
  • A drive cycle may be required after repair

Sources

Diagnostic information is provided for reference only. Confirm the code with a compatible scan tool and follow the vehicle manufacturer's service procedures before replacing components.